Maximum heat output-dry cordwood
90,000 BTU/h
Dimensions
24 1/4" W X 31 1/4" D X 36 1/8" H
Maximum log length
20" (16" recommended)
Average particulate emission rate
0.95 g/h
Recommended heating area
900 - 2,300 ft²
The recommended heating area varies depending on the climatic zones. To validate the values ​​that apply to your place of residence, click here >

DESCRIPTION

  • Extra-large firebox, ideal for large spaces and harsh climates
  • Log loading over depth (north-south)
  • Reinforced appliance top with a C-Cast heat shield
  • Cast iron door and ceramic glass
  • EPA certified at 0.95 g/h 
  • Non-catalytic combustion system
  • Designed and made in Canada
  • Included: pedestal, ash lip, air intake damper and rear air deflector
icon-gov-incentive
Government incentives
Government incentives may apply to this product. For more details, click here >

ACCESSORIES TO COMPLETE YOUR INSTALLATION

    46 3/4" x 54" BLACK STEEL HEARTH PAD

    AC02788

      n/a

        60" CORNER HEARTH PAD

        AC02790

          n/a

            19" KEVLAR THREAD SEWN FIREPLACE GLOVES

            AC07822

              n/a

              SPECIFICATIONS AND MANUALS

              Appliance performance

              Fuel type
              Dry cordwood
              Recommended heating area (3)

              Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.

              900 - 2,300 ft²
              Overall firebox volume
              3.3 ft³
              EPA loading volume
              2.67 ft³
              Maximum burn time (3)

              Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.

              10 h
              Maximum heat output-dry cordwood (4)

              The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

              90,000 BTU/h
              Minimum overall heat output rate (4)

              The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

              (5)

              As measured per CSA B415.1-10 stack loss method.

              15,841 BTU/h (4.64 kW)
              Maximum overall heat output rate (4)

              The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

              (5)

              As measured per CSA B415.1-10 stack loss method.

              57,041 BTU/h (16.72 kW)
              Average overall efficiency-dry cordwood (HHV) (5)

              As measured per CSA B415.1-10 stack loss method.

              (6)

              Higher Heating Value of the fuel.

              71.10%
              Average overall efficiency-dry cordwood (LHV) (5)

              As measured per CSA B415.1-10 stack loss method.

              (7)

              Lower Heating Value of the fuel.

              76.6%
              Optimum efficiency (8)

              Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.

              (9)

              Optimum overall efficiency at a specific burn rate (LHV).

              78%
              Optimum heat transfer efficiency (11)

              The optimum heat transfer efficiency is for the low burn rate and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.

              74%
              Average particulate emission rate (1)

              This appliance is officially tested and certified by an independent agency.

              0.95 g/h
              Average CO (10)

              Carbon monoxyde.

              61.3 g/h

              General features

              Glass type
              Ceramic glass
              Glass surface - W x H
              13 7/8" x 11 3/4"
              Steel thickness-body
              3/16"
              Steel thickness-top
              5/16"
              Firebox size (Width)
              19"
              Firebox size (Height)
              14 1/8"
              Firebox size (Depth)
              21"
              Log positioning
              Loading over depth
              Maximum log length
              20" (16" recommended)
              Baffle type
              High quality vermiculite
              High-efficiency certified appliance
              Yes, EPA 2020 approved
              Canadian Standard (emissions)
              CSA B415.1-10
              USA Standard (emissions)
              EPA
              Canadian Standard (safety)
              ULC S627
              USA Standard (safety)
              UL 1482, UL 737
              Warranty
              Limited 5 years
              Shipping weight
              359 lb (163 kg)

              General features

              Alcove installation approved
              Yes
              Mobile home approved
              Yes, with fresh air intake
              Certified according to applicable standards
              CAN/USA accredited laboratory
              Overall dimension (Width)
              24 1/4"
              Overall dimension (Height)
              36 1/8"
              Overall dimension (Depth)
              31 1/4"
              Premium quality blower included (CFM)
              Optional
              Combustion technology
              Non-catalytic
              Stainless-steel secondary-air system
              Yes
              Flue outlet diameter
              6"
              Recommended chimney diameter
              6"
              Type of chimney
              CAN/ULC S629, UL 103 HT (2100 °F)
              Minimum chimney height
              15"
              Door type
              Single, glass with cast iron frame
              Door opening size (Width)
              16"
              Door opening size (Height)
              11 1/8"
              See more >

              Manuals

              Clearances to combustible materials

              Clearances to combustible materials

              Canada
              Single wall pipeDouble wall pipe
              Clearances to combustible materials - Back wall14 1/2"7 1/2"
              Clearances to combustible materials - Side wall20"20"
              Clearances to combustible materials - Corner12"10"
              Clearances to combustible materials - Base of the unit to ceiling **84"84"

              * Les informations inscrites sur la plaque d'homologation de l'appareil ont toujours préséance sur les informations contenues dans tout autre média publié (manuels, catalogues, circulaires, revues ou sites Web). Consultez le manuel d'installation pour valider tous les dégagements aux matériaux combustibles.

              REVIEWS

              Do you own a Century Heating appliance? Leave us your impressions of our product!

              SUPPORT AND SERVICE

              Need help ?

              Feel free to give us as much detail as possible

              Contact service

              Need parts ?

              Find the replacement parts you need.

              Consult the parts diagram >

              Tips and tricks

              Learn more about wood heating.

              Read articles >

              Warranty

              Take a look at the details of the Century Heating warranty.

              View Warranty >