OPTIONS

CW2900 TRIO 35' Wood insert

CB00022K3
Be the first to rate this product
n/a

Get 5% off on purchases of $3,000 or more.

Discount automatically applied to cart.

Maximum heat output-dry cordwood
75,000 BTU/h
Dimensions
28 1/2" W X 26 1/2" D X 22 5/8" H
Maximum log length
20" (16" recommended)
Average particulate emission rate
2.3 g/h
Recommended heating area
500 - 2,100 ft²
The recommended heating area varies depending on the climatic zones. To validate the values ​​that apply to your place of residence, click here >

DESCRIPTION

  • Large size firebox
  • Spring faceplate adjustment system which easily adapts to any type of hearth
  • Reinforced appliance top with a stainless steel heat shield
  • Cast iron door and ceramic glass
  • EPA certified at 2.3 g/h 
  • Non-catalytic combustion system
  • Designed and made in Canada
  • Included: 34" x 50" faceplate, 6'' liner kit (35' Vortex flexible stainless steel liner, connector, 13'' x 13'' top plate, chimney cap with no screen), air intake damper and 144 CFM blower with thermodisc  
icon-gov-incentive
Government incentives
Government incentives may apply to this product. For more details, click here >

ACCESSORIES TO COMPLETE YOUR INSTALLATION

        SPECIFICATIONS AND MANUALS

        Appliance performance

        Fuel type
        Dry cordwood
        Recommended heating area (3)

        Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.

        500 - 2,100 ft²
        Overall firebox volume
        2.4 ft³
        EPA loading volume
        1.95 ft³
        Maximum burn time (3)

        Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.

        8 h
        Maximum heat output-dry cordwood (4)

        The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

        75,000 BTU/h
        Minimum overall heat output rate (4)

        The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

        (5)

        As measured per CSA B415.1-10 stack loss method.

        14,200 BTU/h (4.16 kW)
        Maximum overall heat output rate (4)

        The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

        (5)

        As measured per CSA B415.1-10 stack loss method.

        44,500 BTU/h (13.04 kW)
        Average overall efficiency-dry cordwood (HHV) (5)

        As measured per CSA B415.1-10 stack loss method.

        (6)

        Higher Heating Value of the fuel.

        72 %
        Average overall efficiency-dry cordwood (LHV) (5)

        As measured per CSA B415.1-10 stack loss method.

        (7)

        Lower Heating Value of the fuel.

        77 %
        Optimum efficiency (8)

        Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.

        (9)

        Optimum overall efficiency at a specific burn rate (LHV).

        79 %
        Optimum heat transfer efficiency (11)

        The optimum heat transfer efficiency is for the low burn rate and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.

        76 %
        Average particulate emission rate (1)

        This appliance is officially tested and certified by an independent agency.

        2.3 g/h
        Average CO (10)

        Carbon monoxyde.

        69 g/h

        General features

        Steel thickness-body
        3/16"
        Steel thickness-top
        1/4"
        Firebox size (Width)
        21"
        Firebox size (Height)
        11 7/8"
        Firebox size (Depth)
        16 1/2"
        Maximum log length
        20" (16" recommended)
        Log positioning
        Loading over width
        Baffle type
        High quality vermiculite
        Minimum fireplace opening (Width)
        28 7/8"
        Minimum fireplace opening (Height)
        23 3/8"
        Minimum fireplace opening (Depth)
        15 3/4"
        High-efficiency certified appliance
        Yes, EPA 2020 approved
        Canadian Standard (emissions)
        CSA B415.1-10
        USA Standard (emissions)
        EPA
        Canadian Standard (safety)
        ULC S628
        USA Standard (safety)
        UL 1482, UL 737
        Warranty
        Limited 5 years
        Shipping weight
        451 lb (205 kg)

        General features

        Alcove installation approved
        No
        Premium quality blower included (CFM)
        144 CFM included
        Certified according to applicable standards
        CAN/USA accredited laboratory
        Combustion technology
        Non-catalytic
        Stainless-steel secondary-air system
        Yes
        Flue outlet diameter
        6"
        Recommended chimney diameter
        6"
        Type of chimney
        CAN/ULC S629, UL 103 HT (2100 °F)
        Minimum chimney height
        12"
        Overall dimension (Width)
        28 1/2"
        Overall dimension (Height)
        22 5/8"
        Overall dimension (Depth)
        26 1/2"
        Door type
        Single, glass with cast iron frame
        Door opening size (Width)
        17 1/2"
        Door opening size (Height)
        9"
        Glass type
        Ceramic glass
        Glass surface - W x H
        14 7/8" x 9 1/4"
        See more >

        Manuals

        Clearances to combustible materials

        Clearances to combustible materials

        Canada
        Clearances to combustible materials - Base of the unit to ceiling **84"
        Clearances to combustible materials - Combustible side mantle to unit9"
        Clearances to combustible materials - Combustible top mantle to unit27"
        Clearances to combustible materials - Combustible side wall to unit16"
        Clearances to combustible materials - Top of the unit to a 12" combustible mantle shelf27"

        * Les informations inscrites sur la plaque d'homologation de l'appareil ont toujours préséance sur les informations contenues dans tout autre média publié (manuels, catalogues, circulaires, revues ou sites Web). Consultez le manuel d'installation pour valider tous les dégagements aux matériaux combustibles.

        REVIEWS

        Do you own a Century Heating appliance? Leave us your impressions of our product!

        SUPPORT AND SERVICE

        Need help ?

        Feel free to give us as much detail as possible

        Contact service

        Need parts ?

        Find the replacement parts you need.

        Consult the parts diagram >

        Tips and tricks

        Learn more about wood heating.

        Read articles >

        Warranty

        Take a look at the details of the Century Heating warranty.

        View Warranty >