OPTIONS

CW2100 Wood insert

CB00027
Be the first to rate this product
n/a

Get 5% off on purchases of $3,000 or more.

Discount automatically applied to cart.

Maximum heat output-dry cordwood
45,000 BTU/h
Dimensions
27 7/8" W X 21 7/8" D X 20 1/8" H
Maximum log length
17" (16" recommended)
Average particulate emission rate
1.5 g/h
Recommended heating area
250 - 1,200 ft²
order-status-icon-check
The recommended heating area varies depending on the climatic zones. To validate the values ​​that apply to your place of residence, click here >

DESCRIPTION

  • Tapered shape (top and sides) designed to fit the smallest masonry hearths
  • Blower with left/right power cord
  • Lightweight steel faceplate with hooks that snap onto the front of the unit
  • Moulded high density refractory panels on the bottom of the appliance and grey bricks on the sides
  • Reinforced appliance top with a stainless steel heat shield
  • Cast iron door and ceramic glass
  • EPA certified at 1.5 g/h 
  • Non-catalytic combustion system
  • Designed and made in Canada
  • Included: 26" x 42" faceplate, air intake damper and 110 CFM blower with thermodisc  
gov-image
Government incentives
Government incentives may apply to this product. For more details, click here >

ACCESSORIES TO COMPLETE YOUR INSTALLATION

    OFFSET LINER ADAPTOR

    AC01214

      n/a

        4' INSULATED FLEX PIPE FOR 5"Ø FRESH AIR INTAKE

        AC02090

          n/a

          SPECIFICATIONS AND MANUALS

          Appliance performance

          Fuel type
          Dry cordwood
          Recommended heating area (3)

          Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.

          250 - 1,200 ft²
          Overall firebox volume
          1.1 ft³
          EPA loading volume
          1.03 ft³
          Maximum burn time (3)

          Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.

          7 h
          Maximum heat output-dry cordwood (4)

          The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

          45,000 BTU/h
          Minimum overall heat output rate (4)

          The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

          (5)

          As measured per CSA B415.1-10 stack loss method.

          8,471 BTU/h (2.48 kW)
          Maximum overall heat output rate (4)

          The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

          (5)

          As measured per CSA B415.1-10 stack loss method.

          31,700 BTU/h (9.29 kW)
          Average overall efficiency-dry cordwood (HHV) (5)

          As measured per CSA B415.1-10 stack loss method.

          (6)

          Higher Heating Value of the fuel.

          75%
          Average overall efficiency-dry cordwood (LHV) (5)

          As measured per CSA B415.1-10 stack loss method.

          (7)

          Lower Heating Value of the fuel.

          80%
          Optimum efficiency (8)

          Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.

          (9)

          Optimum overall efficiency at a specific burn rate (LHV).

          82%
          Optimum heat transfer efficiency (11)

          Carbon monoxyde.

          78%
          Average particulate emission rate (1)

          This appliance is officially tested and certified by an independent agency.

          1.5 g/h
          Average CO (10)

          The optimum heat transfer efficiency is for the low burn rate and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.

          34 g/h

          General features

          Steel thickness-body
          3/16"
          Steel thickness-top
          3/16"
          Firebox size (Width)
          16 3/4"
          Firebox size (Height)
          8 3/4"
          Firebox size (Depth)
          12 3/8"
          Maximum log length
          17" (16" recommended)
          Log positioning
          Loading over width
          Baffle type
          C-Cast or equivalent
          Minimum fireplace opening (Width)
          25"
          Minimum fireplace opening (Height)
          19"
          Minimum fireplace opening (Depth)
          15 1/2"
          High-efficiency certified appliance
          Yes, EPA 2020 approved
          Canadian Standard (emissions)
          CSA B415.1-10
          USA Standard (emissions)
          EPA
          Canadian Standard (safety)
          ULC S628
          USA Standard (safety)
          UL 1482, UL 737
          Warranty
          Limited 5 years
          Shipping weight
          282 lb (kg)

          General features

          Mobile home approved
          No
          Premium quality blower included (CFM)
          90 CFM included
          Certified according to applicable standards
          CAN/USA accredited laboratory
          Combustion technology
          Non-catalytic
          Stainless-steel secondary-air system
          Yes
          Flue outlet diameter
          6"
          Recommended chimney diameter
          6"
          Type of chimney
          CAN/ULC S629, UL 103 HT (2100 °F)
          Minimum chimney height
          12"
          Overall dimension (Width)
          27 7/8"
          Overall dimension (Height)
          20 1/8"
          Overall dimension (Depth)
          21 7/8"
          Door type
          Single, glass with cast iron frame
          Door opening size (Width)
          18 1/4"
          Door opening size (Height)
          7 7/8"
          Glass type
          Ceramic glass
          Glass surface - W x H
          17 3/8" x 8 1/8"
          See more >

          Manuals

          Clearances to combustible materials

          Clearances to combustible materials

          United States
          Clearances to combustible materials - Base of the unit to ceiling **72"72"
          Clearances to combustible materials - Combustible top mantle to unit34"34"
          Clearances to combustible materials - Combustible side wall to unit16"16"

          * Les informations inscrites sur la plaque d'homologation de l'appareil ont toujours préséance sur les informations contenues dans tout autre média publié (manuels, catalogues, circulaires, revues ou sites Web). Consultez le manuel d'installation pour valider tous les dégagements aux matériaux combustibles.

          REVIEWS

          Do you own a Century Heating appliance? Leave us your impressions of our product!

          SUPPORT AND SERVICE

          need-help

          Need help ?

          Feel free to give us as much detail as possible

          Contact service
          need-parts

          Need parts ?

          Find the replacement parts you need.

          Consult the parts diagram >
          need-tricks

          Tips and tricks

          Learn more about wood heating.

          Read articles
          need-questions

          Warranty >

          Take a look at the details of the Century Heating warranty.

          View Warranty >

          Subscribe to our newsletter